This calibration device is designed in accordance with ASTM D5207-03 and related IEC, UL, GB standards for measuring flame temperatures in combustion test equipment.
Position the copper block 55±1mm above the needle flame burner. Ignite the flame; the time for the copper block temperature to rise from 100°C±2°C to 700°C±3°C must be 54±2 seconds to validate the flame for testing.
Perform three measurements, allowing the copper block to cool naturally to <50°C between tests.
ASTM D5207-03: Standard Practice for Confirmation of 20-mm (50-W) and 125-mm (500-W) Test Flames for Small-Scale Burning Tests on Plastic Materials. GB/T 5169.15: Fire Hazard Testing for Electric and Electronic Products - Part 15: Test Flames - 500W Flame Apparatus and Confirmational Test Methods.
IEC 60695-11-3: Fire hazard testing for electric and electronic products - Part 11-3: Test flames - 500W flames - Apparatus and confirmational test methods.
Model | 6015-HD |
Thermocouple | Armored K-type (NiCr/NiAl) fine-wire thermocouple with a 0.5mm diameter sheath. |
Timer | Adjustable range: 0.01-99.99 seconds |
Copper Block Specifications | |
Diameter | Ø9.00±0.01mm |
Length | 19.14±0.02mm |
Bevel Angle | 45±0.5° |
Mass (Pre-drilling) | 10.00g±0.05g |
Material | High-conductivity electrolytic copper |
Surface Finish | Fully polished |