| HD-E819 HAST High Pressure Accelerated Aging Test Chamber Machine Picture Image above for reference only Application This product is suitable for national defense, aerospace, automotive parts, electronic parts, circuit boards, lighting products and other products of the sealing performance. in product design stage, using quickly expose the defects and weaknesses of the products. test the resistance to nastiness and air tightness of the products. Technical Specification | |
| Items | Description |
| Internal dimension | Diameter 400*L500mm; Circular type chamber |
| External dimension | Approx. 1150*980*1850mm(W*D*H) |
| Internal material | SUS# 316 with thickness 3 mm |
| External material | Stainless steel plate material |
| Insulation material | Rock wool and rigid polyurethane foam insulation |
| Steam chamber heating tube | Titanium tube heating, never rust |
| Controller model | PLC control |
| Temperature range | +105C~147C (Vapor temperature) |
| Temperature fluctuations | ±2C |
| Humidity range | 75%~100% (vapor humidity) |
| Temp. & Vapor Humid. | |
| Humidity control stability | ±3%RH |
| Humidity distribution average | ±5%RH |
| Operating Pressure | 1.2~2.89kg(including l atm) |
| Time setting range | 0~999hours |
| Pressurization time | From 0.00kg~1.04kg/cm2,approx.45min |
| Power supply | Single phase 220V 50/60Hz |
| Safety protection | a. Imported high-temperature resistant sealed solenoid valve, using a dual circuit structure to ensure that the pressure is not leaking. b. The whole machine is equipped with overpressure protection, over-temperature protection, one key pressure relief, manual pressure relief multiple safety devices, to ensure the use and safety of users to the maximum extent. c. Counter-pressure door locking device, when there is pressure inside the test chamber, the door of the test chamber can not be opened. |
| Items | Description |
| Internal dimension | Diameter 400*L500mm; Circular type chamber |
| External dimension | Approx. 1150*980*1850mm(W*D*H) |
| Internal material | SUS# 316 with thickness 3 mm |
| External material | Stainless steel plate material |
| Insulation material | Rock wool and rigid polyurethane foam insulation |
| Steam chamber heating tube | Titanium tube heating, never rust |
| Controller model | PLC control |
| Temperature range | +105C~147C (Vapor temperature) |
| Temperature fluctuations | ±2C |
| Humidity range | 75%~100% (vapor humidity) |
| Temp. & Vapor Humid. | |
| Humidity control stability | ±3%RH |
| Humidity distribution average | ±5%RH |
| Operating Pressure | 1.2~2.89kg(including l atm) |
| Time setting range | 0~999hours |
| Pressurization time | From 0.00kg~1.04kg/cm2,approx.45min |
| Power supply | Single phase 220V 50/60Hz |
| Safety protection | a. Imported high-temperature resistant sealed solenoid valve, using a dual circuit structure to ensure that the pressure is not leaking. b. The whole machine is equipped with overpressure protection, over-temperature protection, one key pressure relief, manual pressure relief multiple safety devices, to ensure the use and safety of users to the maximum extent. c. Counter-pressure door locking device, when there is pressure inside the test chamber, the door of the test chamber can not be opened. |