Customization: | Available |
---|---|
Certification: | CE |
Power Supply: | AC 220V, 50Hz |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
This testing machine is custom-designed in accordance with user requirements and relevant standards to evaluate the flame retardant performance of firefighter protective boots.
Secure the protective boot on the fixture and ignite the Bunsen burner. Adjust the flame height to 75mm. Position the specimen holder to ensure each test area contacts the outer flame at a 90° angle. Expose each test area to the flame for 12 seconds, then remove the specimen. Measure the afterflame time (precision: 0.1 seconds).
Model | 6016-HD |
Flame Application Time | Adjustable: 0.01-99H99 / 0.01-99M99 / 0.01-99S99 |
Afterflame Time | Adjustable: 0.01-99H99 / 0.01-99M99 / 0.01-99S99 |
Bunsen Burner | Inner diameter: 11mm |
Fuel Gas | Industrial-grade methane (≥98% purity, user-provided) |
Flame Angle | Adjustable |
Flame Height | Adjustable range: 20-125mm |
Additional Features | Integrated lighting, exhaust system, gas flow/pressure regulators, flow meter, and sample fixture. |
Power Supply | AC 220V, 50Hz |