| Customization: | Available |
|---|---|
| Max Diameter of Workpiece: | <500mm |
| Mass Scope of Workpiece: | <900kg |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
| Dimensions | 250 mm *250 mm * 176 mm(W*D*H) |
| Operating temperature | 5 ºC -400 ºC at room temperature (minimum increment of 1 ºC) |
| Temperature control accuracy | 0.5% (± 0.1 ºC) |
| Heating rate | 0.1 ~ 39 ºC / min arbitrarily set (5 ºC ~ 200 ºC at room temperature), 0.1 ~ 20 ºC / min arbitrary setting (above 200 ºC) |
| Maximum running time | 655 min |
| Maximum order of temperature programming | 9 orders |
| Repeatability of temperature programming | 2% |
| 1. Hydrogen flame detector FID: | |
| Suitable for packed column / capillary column analysis Host or workstation control automatic ignition |
|
| Temperature control range | Room temperature + 5 ºC -400 ºC |
| Minimum detection limit | ≤5 x 10-12 g / s (n-hexadecane) |
| Baseline noise | ≤5 x 10-14 A |
| Baseline drift | ≤1 x 10-13 A (30 min) after turning on and stabilizing for 150 minutes |
| 2. Thermal conductivity detector TCD: | |
| Two-column equilibrium method, suitable for packed column analysis (need to select 2 packed column injectors at the same time) | |
| Temperature control range | Room temperature + 5 ºC -400 ºC |
| Sensitivity | ≥10000mV • ml / mg (n-hexadecane) |
| Detection limit | ≤6 x 10-9 g / ml |
| Baseline noise | ≤0.03mV (the carrier gas is 99.999% hydrogen) |
| Baseline drift | ≤0.1mV / 30min after starting and stabilizing for 150 minutes |
| 3. Flame photometric detector: | |
| Suitable for packed column / capillary column analysis Host or workstation control automatic ignition |
|
| Maximum operating temperature | 400 ºC |
| Minimum detection limit | ≤1 x 10-10 g / s (sulfur in methyl parathion) |
| Minimum detection limit | ≤1 x 10-11 g / s (phosphorus in methyl parathion) |
| Baseline noise | ≤8 x 10-11 A |
| Baseline drift | ≤5 x 10-12 A (30 min) after turning on and stabilizing for 150 minutes |
| 4. Electronic capture detector (ECD): | |
| Suitable for packed column / capillary column analysis, with ECD environmental protection exemption certificate | |
| Detection limit | ≤3 x 10-14 g / ml (BHC) |
| Baseline noise | ≤15 μV |
| Baseline drift | ≤50μV / 30min after starting and stabilizing for 150 minutes |
| Radioactive source Ni 63 | ≤10 mCi (millicuries) |
| 5. NPD detector: | |
| Temperature control range | Room temperature + 5 ºC -400 ºC |
| Detection limit | N≤5 x10-12g / s (azobenzene), P≤5 x 10-13g / s (malathion) |
| Baseline noise | ≤2 x 10-13A |
| Baseline drift | ≤4 x 10-13A / 30 min after starting and stabilizing for 150 minutes |
| 6. PID of photoionization detector | |
| Detection limit | ≤5 x 10-12 g / ml |
| Baseline noise | ≤5 x 10-14A |
| Baseline drift | ≤1.2 x 10-12A (30 min) |