| Customization: | Available |
|---|---|
| Certification: | CE |
| Power Supply: | AC 220V, 50Hz |
| Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
|---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
This tester evaluates the afterflame, flame resistance, and charring tendencies of textiles and safety nets in compliance with GB/T 5455-1997 (JIS 1091) and GB 5725-2009. Optional fixtures available for: FTMS 191-5903: Fire resistance testing of foam materials.
| Parameter | Description |
| Control System | 7-inch color LCD touchscreen + PLC (Programmable Logic Controller) |
| Display System | Real-time monitoring of: • Ignition time • Afterflame time • Flame resistance time |
| Chamber Dimensions | 329(L)×329(W)×767(H)mm |
| Ventilation | • Top: 16ר12.5mm exhaust holes • Sides: 6ר12.5mm holes per side |
| Timing Functions | Adjustable: 0-999.9 seconds for: • Ignition • Afterflame • Flame resistance |
| Burner Angle | 25° from vertical axis |
| Burner Specifications | Nozzle inner diameter: Ø11mm |
| Fuel Gas | Industrial propane or butane (factory-provided butane ≥98% purity) |
| Sample Clamp | Two 2.0mm-thick U-shaped stainless steel plates (422×89mm); inner frame: 356×51mm |
| Weights | 54.5g, 113.4g, 226.8g, 340.2g, 453.6g |
| Key Components | Includes: • Control/combustion chambers • Burner assembly • Solenoid valve • High-voltage igniter • Gas pressure regulator • Lighting system |
| Power Supply | AC 220V, 50Hz |