Major Parameter
| Name | Ultra-fast thermal shock testing machine | |
| Model | HD-600-60 | |
| Performance technical: | ||
| temperature range | -70ºC~200ºC | |
| control precision | ±1.0ºC | |
| Temperature setting and display accuracy | 0.1ºC | |
| overshoot temperature | ≤1ºC | |
| Outer box size approx. | 630*1230*890mm(W*H*D) |
|
| speed of temperature change (air outlet empty) |
-40ºC~+85ºC,10S | |
| +85ºC~-40ºC, 10S | ||
| air output | 5~16SCFM adjustable | |
| temperature control | Air temperature and sample temperature can be switched and controlled. | |
| Temperature Sensor | T-type thermocouple | |
| Operation interface | 10 inch touch screen | |
| Operation method | Program mode and fixed value mode are optional (maximum 30 sets of programs) | |
| Status Display | Temperature setting and flow setting; and real-time display | |
| data store | Data files can be stored in USB | |
| communication method | Network interface, USB, RS484 (provide third-party communication protocol) | |
| PC software | support labview | |
| Data record | Data can be logged to file or transferred to computer | |
| mobile flexibility | 4 swivel casters included | |
| Calibration method | Calibration manually | |
| gas supply | Temperature 20~28 ºC, compressed air or N2 with dew point below 10 ºC | |
| Supply gas condition | Pressure: 0.63-0.77MPa (6.3-7.7kg/C) |
| Supply gas flow | 700L/mim |
| power supply | AC220V 50HZ single phase |
| Operating power | About 4KW |
| Total Weight | About 260KG |







After-Service: