Customization: | Available |
---|---|
Certification: | CE |
Wiring Method: | AC Three-Phase Four-Wire |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Models | HD-H214-750~1500/2000V | |||||
AC parameters | Wiring method | Three-phase five-wire system | ||||
Power supply voltage | 380±10% VAC | |||||
Power supply frequency | 50±5% Hz | |||||
Power factor | > 0.99 | |||||
Max. power feedback efficiency | ≥ 90% | |||||
THD | <3% | |||||
DC parameters | Output current | 200A, 300A, 400A, 500A, 600A, 1000A | ||||
Single channel voltage range | 750V~1500V/2000V | |||||
Voltage accuracy | ± 0.05% F.S | |||||
Voltage resolution | 1mV | |||||
Current accuracy | ± 0.05% F.S | |||||
Current resolution | 1mA | |||||
Current response time | 3ms(10%~90% F.S) | |||||
Current switching time | 5ms(-90%~90% F.S) | |||||
Min. Working Condition Simulation Interval | 10ms | |||||
Upper computer software function | Charging mode | CC, CV, CCCV, CP, Slope etc. | ||||
Discharge mode | CC, CV, CP, CR, Slope etc. | |||||
Other working mode | Still,Working condition test,Pulse test (pulse width 20ms),DCIR etc. | |||||
Test cut-of condition | Battey voltage, current, time, capacity, temperature BMS parameters etc. | |||||
Data export Format | Excel, TXT etc. | |||||
Data recording interval | 10ms | |||||
Editable step | Max.10000 | |||||
Programmable step | Max.10000 | |||||
Nested loop | Max.10 layers | |||||
Software protection | OCP/OVP/UVP/Reverse or wrong connection protection/ Protection for abnormal communication | |||||
Third-party Device Integration | Support linkage of temp. chamber, MTV/MTS, and I/O control box | |||||
Other parameters | IP grade | IP20 | ||||
Working temperature | 0ºC~40ºC | |||||
Cooling method | Forced Fan-cooled | |||||
Noise | <75dB | |||||
Cabinet size(W*D*H mm) | 1600*1100*2000 |