Customization: | Available |
---|---|
Certification: | CE |
Wiring Method: | AC Three-Phase Five-Wire |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1. Cycle Life Test
2. Charging/Discharging Test
3. Battery Capacity Test
4. Temperature Characteristic Test
5. Charge Retention Test
6. High-Speed Working Condition Pulse Test
7. Static/Dynamic SOC Test
8. DCIR Test
1. Support single battery voltage consistence test;
2. Support multi-channel charge-discharge curve comparison;
3. Support multi-channel parallel;
4. Power factor value up to 0.99;
5. Anti-reverse connection and data protection;
6. Battery discharge and energy feedback efficiency ≥90%; 7. Modular design, easy for maintenance;
8. Support RS485/CAN communication, baud rate is changeable;
9. Support DBC import at one-click;
10. Support user-defined BMS values as control/protection parameters;
11. BMS voltage and current following test;
12. User-defined login management rights are supported.
Models | HD-H213-100~500V | |||||
AC parameters | Wiring method | Three-phase five-wire system | ||||
Power supply voltage | 380±10% VAC | |||||
Power supply frequency | 50±5% Hz | |||||
Power factor | > 0.99 | |||||
Max. power feedback efficiency | ≥ 90% | |||||
THD | <5% | |||||
DC parameters | Output current | 100A, 150A, 200A, 300A, 400A, 600A | ||||
Total output power | 10KW-120KW | |||||
Single channel voltage range | 100V~500V | |||||
Voltage accuracy | ± 0.05% F.S | |||||
Voltage resolution | 1mV | |||||
Current accuracy | ± 0.05% F.S | |||||
Current resolution | 1mA | |||||
Current response time | 3ms(10%~90% F.S) | |||||
Current switching time | 5ms(-90%~90% F.S) | |||||
Upper computer software function | Charging mode | CC, CV, CCCV, CP, Slope etc. | ||||
Discharge mode | CC, CV, CP, CR, Slope etc. | |||||
Other working mode | Still,Working condition test,Pulse test (pulse width 20ms),DCIR etc. | |||||
Test cut-of condition | Battey voltage, current, time, capacity, temperature BMS parameters etc. | |||||
Data export Format | Excel, TXT etc. | |||||
Data recording interval | 10ms | |||||
Editable step | Max.10000 | |||||
Programmable step | Max.10000 | |||||
Nested loop | Max.10 layers | |||||
Software protection | OCP/OVP/UVP/Reverse or wrong connection protection/ Protection for abnormal communication | |||||
Third-party Device Integration | Support linkage of temp. chamber, MTV/MTS, and I/O control box | |||||
Other parameters | IP grade | IP20 | ||||
Working temperature | 0ºC~40ºC | |||||
Cooling method | Forced Fan-cooled | |||||
Noise | <75dB | |||||
Cabinet size(W*D*H mm) | 600*850*1030/600*800*1980 |