Gold Member Since 2011
Audited Supplier
Dongguan Haida Equipment Co., Ltd.

Quv Weathering Tester, Quv Accelerated Weathering Tester, Quv Weathering Test Chamber manufacturer / supplier in China, offering Stainless Steel UV Accelerated Weathering Test Machine, Stainless Steel Environmental Temperature Humidity Test Chamber (HD-E702-800L), Environmental Climatic Constant Temperature Humidity Test Chamber and so on.

(/ )

Supplier Homepage Product Environmental Testing Machine Stainless Steel UV Accelerated Weathering Test Machine

Stainless Steel UV Accelerated Weathering Test Machine

FOB Price: US $5,500-9,500 / Piece
Min. Order: 1 Piece
Min. Order FOB Price
1 Piece US $5,500-9,500/ Piece
Get Latest Price
Port: Shenzhen, China
Production Capacity: 60 Sets/Month
Payment Terms: L/C, T/T

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: HD-E703
  • Accuracy Grade: 0.5
  • Display: Needle
  • Weight: 100-500Kg
  • Certificate: ISO9001: 2008
  • Testing Room Size: 450× 1170× 500mm
  • Temperature Range: Rt+10 to 70 Centigrade Degrees
  • Control Mode: Balance Temperature Humidity Control (Bthc)
  • Centre Distance Between The Lamp: 70mm
  • Trademark: Haida
  • Specification: ISO9001: 2008
  • HS Code: 9031809090
  • Type: UV Testers
  • Loading Method: Static Load
  • Control: Computer Control
  • Power Source: AC220V
  • Warranty Period: 12 Months
  • Outside Dimension: 580× 1280× 1450mm
  • Humidity Range: 85% to 98%Rh
  • Distance From Sample to Lamp: 50± 2mm
  • Power: 220V/50Hz /± 10% 6kw
  • Transport Package: Strong Wooden Case
  • Origin: China
Product Description

                               Stainless Steel UV Accelerated Weathering Tester

Introduce: 
UV test machine is applicable for the sunlight resistant test of nonmetallic materials and aging test of artificial light sources. A variety of industrial products can make the reliability test, and this product can simulate the product in the sun, rain, humidity and dew conditions, including damage caused by bleaching, color, brightness down, powder, crack, blur, brittle, intensity decreased and oxidation.
 
Technical parameters:

Studio Size

400W×1140D×390Hmm

Outside dimension

500W×1300D×1360Hmm

Materials

Inside and Outside SUS#304 stainless steel 

Temperature range

RT+10~70°C

Temperature uniformity

±1°C

Temperature fluctuation

±0.5°C

Temperature control

PID SSR control

Humidity range:

 ≥90%RH

Controller

Korean TEMI 880 programmable controller

Control mode

Balance temperature humidity control (BTHC)

Test cycle setting

Illumination, condensation and water spray test cycle is programmable

Lamp power

40W/Piece

Distance from sample to lamp

50±3mm (adjustable) 

Centre distance between the lamp

70mm 

Irradiance

1.0W/cm2

Wavelength ultraviolet light

UV-A: 315-400mm;  UV-B: 280-400mm (8pcs, 1600h lifetime)

Effective irradiation areas

640×1140mm

Irradiation black panel temperature

50°C~70°C

Standard Specimen Size

75×290mm (24pcs can be tested each time)

Required water depth for water channel

25mm, automatically control

Testing time

0~999H, adjustable

Power

220V/50Hz /±10% 5KW

Protection system

Overload short circuit protection, over temperature protection, water lackin

 
Chamber Structure: 
The inner bladder of the chamber is made of imported high-class stainless steel plate while the outer bladder is made of SUS 304 steel plate.
The heating mode adopts inner bladder trough type heating with its rapid temperature rise and even temperature distribution.
 
Control System:
Adopts black aluminum plate to connect temperature sensor and adopts black board temperature meter to control heating so as to ensure more stable temperature.
The radiometer probe is fixed so as to avoid the frequent installation and disassembly.
The radiation quantity adopts the special UV irradiatometer with high-precision display and measurement.
The radiation intensity is not more than 50W/m2.
The illumination and condensation can be controlled independently or alternating and circularly.
 
Test Specimen Mounting: 
The standard test specimen holder accommodates 2 panels 75×150mm. The test panels are actual the side wall of the chamber. To properly seal the chamber, it is important to have every panel holder filled with specimens or blank panels and to have panel holders in place.
 
Design criteria: 
(1) ASTM D4587: Standard Practice for Fluorescent UV-Condensation Exposures of Paint and Related Coatings
(2) ASTM D4799: Standard Practice for Accelerated Weathering Test Conditions and Procedures for Bituminous Materials (Fluorescent UV, Water Spray, and Condensation Method)
(3) ISO 4892-1: Plastics - Methods of Exposure to Laboratory Light Sources - Part 1: General guidance
(4) ISO 4892-3: Plastics - Methods of Exposure to Laboratory Light Sources - Part 3: Fluorescent UV Lamps
(5) ASTM D4329: Standard Practice for Fluorescent UV Exposure of Plastics
(6) AATCC TM186: Weather Resistance: UV Light and Moisture Exposure
(7) ASTM D5208: Standard Practice for Fluorescent Ultraviolet (UV) Exposure of Photodegradable Plastics
(8) IEC 61345: UV Test for Photovaltalic (PV) Modules
 
 
Send your message to this supplier
Avatar
Mr. Sawyer Mak
Manager
*From:
To: Mr. Sawyer Mak
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

Find Similar Products By Category